GDS-1054B Channels 4 Bandwidth DC ~ 50MHz (–3dB) Rise Time 5ns Bandwidth Limit 20MHz Vertical Vertical Sensitivity Resolution 8 bit :1mV*~10V/div Input Coupling AC, DC, GND Input Impedance 1MΩ// 16pF approx. DC Gain Accuracy* ±3% Polarity Normal & Invert Maximum Input Voltage 300Vrms, CAT I (300Vrms CAT II with GTP-070B- 4/100B-4 10:1 probe) Offset Position Range 1mV/div : ±1.25V 2mV/div ~ 100mV/div : ±2.5V 200mV/div ~ 10V/div : ±125V Waveform Signal Process Plus, -, ×, ÷, FFT, FFTrms, User Defined Expression FFT: Spectral magnitude. Set FFT Vertical Scale to Linear RMS or dBV RMS, and FFT Window to Rectangular, Hamming, Hanning, or Blackman- Harris Trigger Source CH1, CH2, CH3*, CH4*, Line, EXT** *four channel models only. **two channel models only. Trigger Mode Auto (supports Roll Mode for 100 ms/div and slower), Normal, Single Sequence Trigger Type Edge, Pulse Width, Video, Pulse Runt, Rise & Fall, Timeout, Alternate, Event-Delay(1~65535 events), Time-Delay(Duration, 4nS~10S), Bus Holdoff range 4ns to 10s Coupling AC, DC, LF rej., Hf rej., Noise rej. Sensitivity 1div External Trigger Range ±15V Sensitivity DC ~ 100MHz Approx. 100mV 100MHz ~ 200MHz Approx. 150mV Input Impedance 1MΩ±3%~16pF Horizontal Time base Range 5ns/div ~ 100s/div (1-2-5 increments) ROLL: 100ms/div ~ 100s/div Pre-trigger 10 div maximum Post-trigger 2,000,000 div maximum Timebase Accuracy ±50 ppm over any ≥ 1 ms time interval Real Time Sample Rate 1GSa/s max. Record Length Max. 10Mpts Acquisition Mode Normal, Average, Peak Detect, Single Peak Detection 2nS (typical) Average selectable from 2 to 256 X-Y Mode X-Axis Input Channel 1; Channel 3* *four channel models only Y-Axis Input Channel 2; Channel 4* *four channel models only Phase Shift ±3° at 100kHz Cursors and Measurement Cursors Amplitude, Time, Gating available; Unit: Seconds(s), Hz(1/s), Phase(degree), Ration(%) Automatic Measurement 36 sets: Pk-Pk, Max, Min, Amplitude, High, Low, Mean, Cycle Mean, RMS, Cycle RMS, Area, Cycle Area, ROVShoot, FOVShoot, RPREShoot, FPREShoot, Frequency, Period, RiseTime, FallTime, +Width, -Width, Duty Cycle, +Pulses, -Pulses, +Edges, -Edges, FRR, FRF, FFR, FFF, LRR, LRF, LFR, LFF, Phase Cursors measurement Voltage difference between cursors ( ΔV) Time difference between cursors ( ΔT) Auto counter 6 digits, range from 2Hz minimum to the rated bandwidth Control Panel Function Autoset Single-button, automatic setup of all channels for vertical, horizontal and trigger systems, with undo Autoset Save Setup 20set Save Waveform 24set Display TFT LCD Type 7″ TFT WVGA color display Display Resolution 800 horizontal × 480 vertical pixels (WVGA) Interpolation Sin(x)/x Waveform Display Dots, vectors, variable persistence (16ms~4s), infinite persistence Waveform Update Rate 50,000 waveforms per second, maximum Display Graticule 8 x 10 divisions Display Mode YT, XY Interface USB Port USB 2.0 High-speed host port X1, USB High-speed 2.0 device port X1 Ethernet Port(LAN) RJ-45 connector, 10/100Mbps with HP Auto-MDIX Go-NoGo BNC 5V Max/10mA TTL open collector output Kensington Style Lock Rear-panel security slot connects to standard Kensington-style lock Miscellaneous Multi-language menu Available Operation Environment Temperature: 0°C to 50°C. Relative Humidity ≤80% at 40°C or below; ≤ 45% at 41°C ~ 50°C On-line help Available Dimensions 380mmX208mmX127.3mm Weight 2.8kg Download Funtion Module Download Firmware Download App Software Download PC Software Download USB Driver Download LabView Driver Download Firmware Download User Manual Download Quick Start Guide Download Programming Manual Download Datasheet Download Brochure Download
Oscilloscope GwInstek GDS-1054B
Oscilloscope GwInstek GDS-1054B
Đánh giá
Chưa có đánh giá nào.